Deys Betontechniek Nederland BV
Gelreweg 5, 3843 AN Harderwijk
Postbus 330, 3840 AH Harderwijk
http://www.deys.nl

Telephone +31 (0)341 41 51 48
(24 hr / day)
Fax (0341) 42 54 90
info@deys.nl

BETEC 110 / 140 / 180

Description

BETEC 110, 140 and 180 are so-called non- (wet) shrinking moulding mortars based on Portland cement which are applied in the heavy and medium-heavy industry as well as in road and hydraulic engineering.

TypeGrain structure [mm]Particulars
1100-1 
1400-4 
1800-8 
Quality control

During manufacturing only high-quality aggregates are used, which meet the strictest requirements. During the production process as well as during the final stages these materials are extensively tested for quality, not only in our own laboratory, but also in independent acknowledged institutes.

Application areas Advantages
  • Grouting of constructions with heavy static and/or dynamic load, like foundations of machines, railway constructions, concrete constructions and joint junctions
  • Fastening reinforcement bars and anchors as well as grouting holes in concrete structures
  • Injecting gain holes in columns and joints in prefab concrete structures
  • Under-water repairs
  •  
  • Products ready for use, which are easy to process and environment-friendly
  • Chromate reduced
  • Checked volume increase
  • No plastic shrinkage
  • Very high early and final strengths, therefore loading is possible soon after application
  • Resistant to frost and gritting materials, like salt
  • High fluidity
  • Free of chlorides and other corrosive aggregates
  • Contain no aluminous cement
  • Comply with the requirements drawn up for prestressed concrete
  • Very good adhesion to concrete and steel
  • Highly resistant to oil and grease
  • Can be pumped, vibrated or poured without any danger of de-mixing
Packaging and storage
25 kg bags. Dry and frostproof, storage life 12 months in the original and closed packaging.
Precautions
Refer to safety sheets.

 

Article Code110140180
Kind of mortarmoulding mortarmoulding mortarmoulding mortar
Type of Mortar [mm]148
Moulding height [mm]5-5020-20050-300
At armed constructies  moulding height can change
Class of strengthK70K70K70
Environmental degreexo t/m xa3xo t/m xa3xo t/m xa3
Volume increase [%]> 0.1 and < 2.0> 0.1 and < 2.0> 0.1 and < 2.0
Yield measurement [mm]   
 • after 5 minutes≥,700≥,700≥,700
 • after 30 minutes≥,600≥,600≥,600
Desiccation shrinkage after 7 days [mm/m]0.540.620.46
(measurements of shrinkage on experimental patches that received no curing)   
Water segregation (bleeding)nonenonenone
Min. processing temp.** [°C]555
Max. processing temp. [°C]353535
Rel. humidity foundation soilmoderately dampmoderately dampmoderately damp
Bond strength to concrete [N/mm²]> 2> 2> 2
Water dosagerefer to front of package
E-module [N/mm²]330003470035000
Calculation of amount of dry mortar [kg/m³]195019902060
Density of mixed mortar (kg/dm³)2.22.22.3
MPA freeze-thaw salt reportPresentPresentPresent
Compressive strength [N/mm²] (20°C)   
 • 1 day48.054.044.0
 • 3 days63.065.061.0
 • 7 days79.083.078.0
 • 28 days94.096.090.0
 • 90 days104.0107.099.0
Flexural-tensile strength [N/mm²] (20°C)   
 • 1 day7.57.56.5
 • 7 days11.511.59.5
 • 28 days12.012.010.0
 • 90 days12.512.510.5

Complies with CUR recommendation 24 **At temperatures below 5ºC measures for winter conditions must be taken (material applicable till 5ºC)

Liability

The technical instructions and recommendations we provide on the basis of our experience and to the best of our knowledge, are entirely without obligation and merely provide an indication. Not all facts, problems and queries that occur during practical application can be included in a general documentation sheet. Our recommendations and instructions do not commit us to any legal obligations as a result of the purchase and application of our products. Any deviating agreements made by our employees that are not included in our datasheets will only be lawful providing they have been confirmed in writing by the management. Our raw materials, semi-finished products and products comply with the most stringent quality standards. This does not relieve the user of their responsibility to test our products prior to their application. Our general trading and delivery conditions, which we are happy to forward to you on demand, are and remain applicable at all times.
This specification sheet supersedes any previous versions.