Deys Betontechniek B.V.

Giet- en ondersabelingsmortels,Betonreparatie producten, Injectieproducten, Kunststoffen, Mortelpompen, Voegovergang constructies

Deys Targets
  • Chemical-and petrochemical plants

  • Delta works

  • Sea Lock IJmuiden

  • Harbours

  • Industry

  • Offshore

  • Powerplants

  • Department of public works

  • Railways

  • Utility

  • Airports

  • Water treatment

  • Road and water construction

  • windmills

    Windturbines

BETEC Cable Grout 250

Description

BETEC Cable Grout 250 (HOZ) is a so-called non- (wet) shrinking injecting mortar based on portland cement, but it can also be moulded because of its excellent fluidity. BETEC Cable Grout 250 (HOZ) has been specially developed and tested to inject prestressing ducts.  

Type Grain structure [mm] Particulars
250 < 0.15  
Quality control

During manufacturing only high-quality aggregates are used, which meet the strictest requirements. During the production process as well as during the final stages these materials are extensively tested for quality, not only in our own laboratory, but also in independent acknowledged institutes.

Application areas Advantages
  • Injecting mortar for channels for prestressing steel (piles for example)
  • Injecting mortar for anchorages
  • Injecting mortar for severall concrete connections
  • Injection mortar for cracks
  • Product ready for use, which is easy to process and environment-friendly
  • Chromate reduced
  • Checked volume increase
  • Geen bleeding, after pressing not necessary anymore
  • No plastic shrinkage
  • Very high early and final strengths, therefore loading is possible soon after application
  • Can be used both for horizontal as well for vertical injections
  • High fluidity
  • Free of chlorides and other corrosive aggregates
  • Contains no aluminous cement
  • Complies with the requirements drawn up for prestressed concrete
  • Very good adhesion to concrete and steel
  • Highly resistant to oil and grease
  • Can be pumped, vibrated or poured without any danger of de-mixing
Packaging and storage
20 kg bags.Dry and frostproof, storage life 12 months in the original and closed packaging.
Precautions
Refer to safety sheets.
Article Code 250
Kind of mortar Injecting mortar ( also pourable )
Type of mortar [mm] ≤, 0.15
Class of strength K70
Volume increase [%] 1-3
according to Plate Cane EN 445-1996 after 24 hours 1.1
According to Tube test EN 445-2008 after 24 hrs 0.7
Water segregation (bleeding) after 3 hours none
According to EN 445-1996 and EN 445-2008  
Marsh cone EN 480 1996-2008 after 5 minutes ≤ 18
After 30 minutes ≤ 20
Wcf .30
Cement Komo EN 934-4  
Certificate nr 1147-10-1028  
Min. processing temperature ** [°C] 5
Max. processing temperature [°C] 35
Water dosage refer to front of package
Calculation of amount of dry mortar [kg/m³] 1600
Density of mixed mortar (kg/dm³) 2.0
Compressive strength [N/mm²](20°C)  
 • 1 day 50.0
 • 7 days 75.0
 • 28 days 85.0
Flexural-tensile strength [N/mm²] (20°C)  
 • 1 day 7.2
 • 7 days 9.0
 • 28 days 11.0
   
Complies with all demands for pre-mixed mortar for prestressing ducts horizontal as well as vertical **At temperatures below 5 ºC measures for winter conditions must be taken (material applicable till -5ºC)
Processing advice
General Processing Advice Moulding mortar (cement-bound) [A]
Please contact us, we will send you the information.

Liability

The technical instructions and recommendations we provide on the basis of our experience and to the best of our knowledge, are entirely without obligation and merely provide an indication. Not all facts, problems and queries that occur during practical application can be included in a general documentation sheet. Our recommendations and instructions do not commit us to any legal obligations as a result of the purchase and application of our products. Any deviating agreements made by our employees that are not included in our datasheets will only be lawful providing they have been confirmed in writing by the management. Our raw materials, semi-finished products and products comply with the most stringent quality standards. This does not relieve the user of their responsibility to test our products prior to their application. Our general trading and delivery conditions, which we are happy to forward to you on demand, are and remain applicable at all times.
This specification sheet supersedes any previous versions.